Sign In | Join Free | My himfr.com
Home > VFD Fan Speed Control >

3 Phase 132kw 176HP VFD Fan Speed Control 380V For Submersible Pump

CHIFON ELECTRIC CO.,LIMITED
Contact Now
    Buy cheap 3 Phase 132kw 176HP VFD Fan Speed Control 380V For Submersible Pump from wholesalers
     
    Buy cheap 3 Phase 132kw 176HP VFD Fan Speed Control 380V For Submersible Pump from wholesalers
    • Buy cheap 3 Phase 132kw 176HP VFD Fan Speed Control 380V For Submersible Pump from wholesalers
    • Buy cheap 3 Phase 132kw 176HP VFD Fan Speed Control 380V For Submersible Pump from wholesalers
    • Buy cheap 3 Phase 132kw 176HP VFD Fan Speed Control 380V For Submersible Pump from wholesalers

    3 Phase 132kw 176HP VFD Fan Speed Control 380V For Submersible Pump

    Ask Lasest Price
    Brand Name : CHIFON
    Model Number : FPR500A-132G/160P-T4
    Certification : CE,ISO,SGS,EAC
    Payment Terms : L/C, T/T, Paypal
    Supply Ability : 10000pcs per month
    Delivery Time : sample order 2 working days, bulk order 7-10 working days
    • Product Details
    • Company Profile

    3 Phase 132kw 176HP VFD Fan Speed Control 380V For Submersible Pump


    132kw Forced Convection Variable Speed Drive VFD 380V 3 Phase For Foaming Machine



    What is a Variable Speed Drive?


    A variable frequency drive (VFD) is an electronic device that controls the speed of AC induction motors. Before we look at how this works and how it can be used, we should look at the history of motor controllers, and also how the induction motor itself works.

    It has always been useful to control the speed of electric motors used in industry. Nearly every process that uses a motor will benefit from speed control. Not only is the process generally improved, but in many cases (particularly with pumps and fans) these are considerable energy savings.

    Before electronic controllers were available, motors were controlled in various ways, for example by controlling the field current on a DC motor using a series of resistors, or by using other motors. However, when Thyristors, the first power semiconductors, became available in the 1950s, it became possible to control the armature voltage, and therefore the speed, of a DC motor using phase control. These DC drives are still manufactured and in wide use today.

    Why do we need a VFD?

    1 - Reduce Energy Consumption and Energy Costs

    If you have an application that does not need to be run at full speed, then you can cut down energy costs by controlling the motor with a variable frequency drive, which is one of the benefits of Variable Frequency Drives. VFDs allow you to match the speed of the motor-driven equipment to the load requirement. There is no other method of AC electric motor control that allows you to accomplish this.

    Electric motor systems are responsible for more than 65% of the power consumption in the industry today. Optimizing motor control systems by installing or upgrading to VFDs can reduce energy consumption in your facility by as much as 70%. Additionally, the utilization of VFDs improves product quality and reduces production costs. Combining energy efficiency tax incentives, and utility rebates, returns on investment for VFD installations can be as little as 6 months.

    2 - Increase Production Through Tighter Process Control

    By operating your motors at the most efficient speed for your application, fewer mistakes will occur, and thus, production levels will increase, which earns your company higher revenues. On conveyors and belts, you eliminate jerks on start-up allowing high throughput.

    3 - Extend Equipment Life and Reduce Maintenance

    Your equipment will last longer and will have less downtime due to maintenance when it’s controlled by VFDs ensuring optimal motor application speed. Because of the VFDs optimal control of the motor’s frequency and voltage, the VFD will offer better protection for your motor from issues such as electrothermal overloads, phase protection, under-voltage, overvoltage, etc.. When you start a load with a VFD you will not subject the motor or driven load to the “instant shock” of across the line starting, but can start smoothly, thereby eliminating belt, gear, and bearing wear. It also is an excellent way to reduce and/or eliminate water hammers since we can have smooth acceleration and deceleration cycles.


    FPR500A Product specifications


    Basic FunctionSpecification
    Maximum output frequency0~500Hz
    Carrier frequency0.5kHz~16.0kHz;According to the load characteristics, carrier
    frequency can be adjusted automatically
    Input frequencyRange :47~63Hz
    Control modeV/F Open/closed loop vector control(SVC/FVC)
    Speed range1:50(Vector mode 0 ) 1Hz/150% rated torque
    Overload capability

    G type:150% rated current for 60s;

    180% rated current for 3s
    P type:120% rated current for 60s;

    150% rated current for 3s

    Torque boostAuto Torque boost Manual Torque boost; 0.1%~30.0%.
    V/F curve V/FFour modes : Line , Multi-point , Square V/F curve, V/F separation
    Jog controlJog frequency range:0.00Hz to F0-10(Max frequency)
    Accelerate/Decelerate curveLine or S-curve Acc/Dec mode, four kinds of Acc/Dec time Range
    of Acc/Dec Time0.0~65000.00s.
    DC brakeDC brake frequency: 0.00Hz to Maximum frequency
    brake time: 0.0 to 36.0s
    brake current value: 0.0 to 100%
    Simple PLC, Multi-speed16-speed operating through built-in PLC or control terminal
    Built-in PIDClose loop control system can be formed easily by using PID
    Automatic voltage
    regulating (AVR)
    Output voltage is regulated when voltage of the power network changes
    Overvoltage and over current
    stall control
    During operation automatically limits the inverter output current
    and bus voltage, to prevent fan over current and overvoltage trip.
    Rapid current limiting
    function
    Minimizing flow failures, protect the normal operation of the inverter
    Instantaneous stop non-stopLoad feedback energy compensation voltage is reduced and continues to maintain a short time when change is momentarily interrupted.
    Speed tracking startFor high-speed rotation of the motor speed identification, impact-
    free smooth start
    Rapid current limitRapid software and hardware limiting technology to avoid
    frequent converter over current fault.
    Virtual IOFive sets of virtual DO, five sets of virtual DI, enables easy logic control.
    Timing ControlTiming control: set the time range 0.0Min~6500.0Hour
    Multi-motor
    switch
    Two independent motor parameters, enabling two motors switching control
    Bus SupportTwo independent Modbus communication, CAN-Link
    Command sourceGiven the control panel, control terminal, serial communication port given. It
    can be switched by a variety of ways.
    Torque boostAuto Torque boost Manual Torque boost ; 0.1%~30.0%.
    Frequency sourceNine kinds of frequency sources: digital setting, analog voltage setting, analog current setting, pulse setting, or serial port and so on. It can be switched by a variety of ways.
    Auxiliary
    frequency source
    Nine kinds of auxiliary frequency source. Flexible implementation of auxiliary
    frequency tuning, frequency synthesis.
    Input terminalSix digital input terminals, one only supports 50khz high pulse input
    Two analog input terminals, one support 0V~10V voltage input
    One support 0 ~ 10V voltage input or 0 ~ 20mA current input
    Output
    terminal
    One high-speed pulse output terminal (optional open collector type), support of
    square wave 0 ~ 50kHz signal output
    One digital output terminal
    One relay output terminals
    Two analog output terminals, support 0 ~ 20mA current output or 0 ~ 10V
    voltage output
    Display and operation
    LED displayDisplay parameters and status information

    The key lock and function selection


    Achieve some or all of the keys locked, scope definition section keys
    to prevent misuse.
    Protection functionInput/output phase failure protection ,Overcurrent protection ;Over
    voltage protection; Undervoltage protection; Overheat protection ;
    Overload protection
    OptionsBrake assembly, PG card
    Environment
    Application environmentIn-door, free from direct sunlight, dust , corrosive gas, combustible gas, oil mist , steam , water drop and salt .
    AltitudeLower than 1000m
    VibrationLess than 5.9m/s(0.6g)

    Field Application Photos:



    Product packaging:




    Quality 3 Phase 132kw 176HP VFD Fan Speed Control 380V For Submersible Pump for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: CHIFON ELECTRIC CO.,LIMITED
    *Subject:
    *Message:
    Characters Remaining: (0/3000)