    Brand Name : CHIFON
    Model Number : FPR500A-0.75G-S2
    Certification : CE,ISO,SGS,EAC
    Payment Terms : L/C, T/T, Paypal
    Supply Ability : 10000pcs per month
    Delivery Time : sample order 2 working days, bulk order 7-10 working days
    • Product Details
    • Company Profile

    Vector Single Phase Motor VSD 220v 1hp 2hp 3hp Variable Frequency Drive EAC

    Europe hot-sale Single Phase 220v Vector VSD 1hp 2hp 3hp For Water Pump Control

    Power class


    Low voltage

    Single-phase 220v±15% 0.4-2.2kw
    Three-phase 380V±15% 0.75-315kw



    Maintenance of VFD


    Keeping a Spare VFD

    Many applications that utilize a variable frequency drive (VFD) are critical and can’t afford to have extensive downtime. One option that many opt for is to keep a spare VFD on the shelf, ready to switch out if the need arises. If you are not careful, however, that VFD may not be ready to use when you need it. Below are several things to look for to make sure your spare VFD is ready to pull from long term storage and put right in to service.

    Environmental Concerns

    One of the easiest issues to address is where and how you are storing the VFD. Make sure that it is cool, clean, and dry. Common issues we see are that the warehouse where a spare VFD is stored has excessive moisture, dust, or even animal problems. The number of issues we have seen when mice or other animals decide to make nests in VFDs is higher than most people realize, and dust and water always present a problem.

    Another issue to monitor is temperature. Most inverters are rated to run at temperature similar to 0-40°C. VFDs can be stored at slightly more extreme temperatures than they can be run at, but make sure to consult the manual for your VFDs to find what conditions are recommended.

    Maintenance of Capacitors

    Electrolytic capacitors are used in almost all low voltage drives, and some medium voltage as well. These capacitors are filled with an electrolytic gel which gives them their name. As these capacitors sit without being used, the gel starts to dry up and cause issues. Some medium voltage VFDs use dry film capacitors which do not encounter these problems, so a crucial aspect of servicing your drives is to identify what type of components are inside.

    One of the best things you can do for your VFD is to energize it yearly. When you perform the annual preventative maintenance on your other drives, find a way to energize the stored VFD. If electrolytic capacitors sit for more than a year without being energized, you need to make sure to reform the capacitors before putting it into service, which takes valuable time at what could be a moment when your process is down. Most electrolytic capacitors only have a 5-7 year shelf life, so if you go too long without energizing or reforming capacitors, you may find it is too late to save the VFD without performing actual repairs.

    One issue with just reforming capacitors on VFDs is that you can only reform the DC bus capacitors, and capacitors that are on the printed circuit boards are not reformed. That is why the best recommendation is to actually go a step past energizing stored VFDs every year and to actually rotate out equipment at every annual preventative maintenance service to keep all VFDs in their best-running shape.



    Products Specifications:


    Basic FunctionSpecification
    Maximum output frequency0~500Hz
    Carrier frequency0.5kHz~16.0kHz;According to the load characteristics, carrier
    frequency can be adjusted automatically
    Input frequencyRange :47~63Hz
    Control modeV/F Open/closed loop vector control(SVC/FVC)
    Speed range1:50(Vector mode 0 ) 1Hz/150% rated torque
    Overload capabilityG type:150% rated current for 60s;
    180% rated current for 3s
    P type:120% rated current for 60s;
    150% rated current for 3s
    Torque boostAuto Torque boost Manual Torque boost; 0.1%~30.0%.
    V/F curve V/FFour modes : Line , Multi-point , Square V/F curve, V/F separation
    Jog controlJog frequency range:0.00Hz to F0-10(Max frequency)
    Accelerate/Decelerate curveLine or S-curve Acc/Dec mode, four kinds of Acc/Dec time Range
    of Acc/Dec Time0.0~65000.00s.
    DC brakeDC brake frequency: 0.00Hz to Maximum frequency
    brake time: 0.0 to 36.0s
    brake current value: 0.0 to 100%
    Simple PLC, Multi-speed16-speed operating through built-in PLC or control terminal
    Built-in PIDClose loop control system can be formed easily by using PID
    Automatic voltage
    regulating (AVR)
    Output voltage is regulated when voltage of the power network changes
    Overvoltage and over current
    stall control
    During operation automatically limits the inverter output current
    and bus voltage, to prevent fan over current and overvoltage trip.
    Rapid current limiting
    function
    Minimizing flow failures, protect the normal operation of the inverter
    Instantaneous stop non-stopLoad feedback energy compensation voltage is reduced and continues to maintain a short time when change is momentarily interrupted.
    Speed tracking startFor high-speed rotation of the motor speed identification, impact-
    free smooth start
    Rapid current limitRapid software and hardware limiting technology to avoid
    frequent converter over current fault.
    Virtual IOFive sets of virtual DO, five sets of virtual DI, enables easy logic control.
    Timing ControlTiming control: set the time range 0.0Min~6500.0Hour
    Multi-motor
    switch
    Two independent motor parameters, enabling two motors switching control
    Bus SupportTwo independent Modbus communication, CAN-Link
    Command sourceGiven the control panel, control terminal, serial communication port given. It
    can be switched by a variety of ways.
    Torque boostAuto Torque boost Manual Torque boost ; 0.1%~30.0%.
    Frequency sourceNine kinds of frequency sources: digital setting, analog voltage setting, analog current setting, pulse setting, or serial port and so on. It can be switched by a variety of ways.
    Auxiliary
    frequency source
    Nine kinds of auxiliary frequency source. Flexible implementation of auxiliary
    frequency tuning, frequency synthesis.
    Input terminalSix digital input terminals, one only supports 50khz high pulse input
    Two analog input terminals, one support 0V~10V voltage input
    One support 0 ~ 10V voltage input or 0 ~ 20mA current input
    Output
    terminal
    One high-speed pulse output terminal (optional open collector type), support of
    square wave 0 ~ 50kHz signal output
    One digital output terminal
    One relay output terminals
    Two analog output terminals, support 0 ~ 20mA current output or 0 ~ 10V
    voltage output
    Display and operation
    LED displayDisplay parameters and status information
    The key lock and function selectionAchieve some or all of the keys locked, scope definition section keys
    to prevent misuse.
    Protection functionInput/output phase failure protection ,Overcurrent protection ;Over
    voltage protection; Undervoltage protection; Overheat protection ;
    Overload protection
    OptionsBrake assembly, PG card
    Environment
    Application environmentIn-door, free from direct sunlight, dust , corrosive gas, combustible gas, oil mist , steam , water drop and salt .
    AltitudeLower than 1000m
    VibrationLess than 5.9m/s(0.6g)